EmissionsLookup
Non-Compliance Clean Water Act

LIGHTHOUSE LOFTS

Quick Summary

  • Currently out of compliance in at least one environmental program (CAA, CWA, or RCRA).
  • Assessed $0 in total penalties since records began.
Address
2850 ZUNI ST
DENVER, CO 80211
View on map ↗
County
DENVER County
Inspections
1 · last May 24, 2022
Total Penalties
$0
Registry ID
110070102775

Compliance Status (Last 12 Quarters)

Number of calendar quarters, out of the last 12, in which this facility was in violation of its permit. Zero means no recorded violations in that program over the past three years.

7
Water (CWA)
Qtrs Non-Compliant

Discharge Limit Exceedances

Instances where this facility's reported discharge monitoring results exceeded its permitted limits under the Clean Water Act. Exceedance percentage shows how far over the permit limit the discharge was.

Pollutant Violation Reported Limit Exceedance Period Status
Selenium, potentially dissolvd DMR, Limited - Numeric Violation 0.00 mg/L 0.00 +7% Dec 2024 Open
Selenium, potentially dissolvd DMR, Limited - Numeric Violation 0.00 mg/L 0.00 +7% Nov 2024 Open
Solids, total suspended DMR, Limited - Overdue 66.00 mg/L 45.00 +47% Jul 2024 Resolved
Solids, total suspended DMR, Limited - Numeric Violation 66.00 mg/L 45.00 +47% Jul 2024 Open
Solids, total suspended DMR, Limited - Overdue 37.00 mg/L 30.00 +23% Jul 2024 Resolved
Solids, total suspended DMR, Limited - Numeric Violation 37.00 mg/L 30.00 +23% Jul 2024 Open
Solids, total suspended DMR, Limited - Overdue 77.00 mg/L 45.00 +71% May 2023 Resolved
Solids, total suspended DMR, Limited - Numeric Violation 77.00 mg/L 45.00 +71% May 2023 Open
Solids, total suspended DMR, Limited - Numeric Violation 406.00 mg/L 30.00 +1,253% Jun 2022 Open
Copper, potentially dissolved DMR, Limited - Numeric Violation 0.02 mg/L 0.02 +11% Jun 2022 Open
Solids, total suspended DMR, Limited - Numeric Violation 406.00 mg/L 45.00 +802% Jun 2022 Open
Copper, potentially dissolved DMR, Limited - Numeric Violation 0.02 mg/L 0.02 +1% Apr 2022 Open
Chromium, hexavalent dissolved [as Cr] DMR, Limited - Numeric Violation 0.02 mg/L 0.01 +82% Apr 2022 Resolved
Selenium, potentially dissolvd DMR, Limited - Numeric Violation 0.01 mg/L 0.00 +74% Apr 2022 Resolved
Chromium, hexavalent dissolved [as Cr] DMR, Limited - Numeric Violation 0.02 mg/L 0.02 +25% Apr 2022 Open
Chromium, hexavalent dissolved [as Cr] DMR, Limited - Numeric Violation 0.02 mg/L 0.01 +82% Mar 2022 Resolved
Chromium, hexavalent dissolved [as Cr] DMR, Limited - Numeric Violation 0.02 mg/L 0.02 +25% Mar 2022 Open
Chromium, hexavalent dissolved [as Cr] DMR, Limited - Numeric Violation 0.02 mg/L 0.01 +82% Feb 2022 Resolved
Chromium, hexavalent dissolved [as Cr] DMR, Limited - Numeric Violation 0.02 mg/L 0.02 +25% Feb 2022 Open
Chromium, hexavalent dissolved [as Cr] DMR, Limited - Numeric Violation 0.02 mg/L 0.01 +55% Jan 2022 Resolved
Chromium, hexavalent dissolved [as Cr] DMR, Limited - Numeric Violation 0.02 mg/L 0.02 +6% Jan 2022 Open
Selenium, potentially dissolvd DMR, Limited - Numeric Violation 0.01 mg/L 0.00 +161% Jan 2022 Resolved
Selenium, potentially dissolvd DMR, Limited - Numeric Violation 0.02 mg/L 0.02 +3% Dec 2021 Open
Selenium, potentially dissolvd DMR, Limited - Numeric Violation 0.02 mg/L 0.00 +313% Dec 2021 Resolved
Tetrachloroethylene DMR, Limited - Numeric Violation 0.01 mg/L 0.01 +20% Dec 2021 Open
Selenium, potentially dissolvd DMR, Limited - Numeric Violation 0.02 mg/L 0.00 +291% Nov 2021 Resolved
Selenium, potentially dissolvd DMR, Limited - Numeric Violation 0.02 mg/L 0.02 +3% Oct 2021 Open
Selenium, potentially dissolvd DMR, Limited - Numeric Violation 0.02 mg/L 0.00 +313% Oct 2021 Resolved
Selenium, potentially dissolvd DMR, Limited - Numeric Violation 0.02 mg/L 0.00 +248% Sep 2021 Resolved
Selenium, potentially dissolvd DMR, Limited - Numeric Violation 0.02 mg/L 0.00 +248% Aug 2021 Resolved
Solids, total suspended DMR, Limited - Numeric Violation 102.00 mg/L 45.00 +127% Jul 2021 Open
Selenium, potentially dissolvd DMR, Limited - Numeric Violation 0.02 mg/L 0.00 +248% Jul 2021 Resolved
Solids, total suspended DMR, Limited - Numeric Violation 102.00 mg/L 30.00 +240% Jul 2021 Open
Selenium, potentially dissolvd DMR, Limited - Numeric Violation 0.02 mg/L 0.00 +248% Jun 2021 Resolved
Tetrachloroethylene DMR, Limited - Numeric Violation 0.01 mg/L 0.01 +6% Jun 2021 Resolved
Selenium, potentially dissolvd DMR, Limited - Numeric Violation 0.02 mg/L 0.00 +400% May 2021 Resolved
Selenium, potentially dissolvd DMR, Limited - Numeric Violation 0.02 mg/L 0.02 +25% May 2021 Open
Tetrachloroethylene DMR, Limited - Numeric Violation 0.01 mg/L 0.01 +37% May 2021 Resolved
Tetrachloroethylene DMR, Limited - Numeric Violation 0.01 mg/L 0.01 +70% Apr 2021 Resolved
Selenium, potentially dissolvd DMR, Limited - Numeric Violation 0.02 mg/L 0.00 +313% Apr 2021 Resolved
Selenium, potentially dissolvd DMR, Limited - Numeric Violation 0.02 mg/L 0.02 +3% Apr 2021 Open
Selenium, potentially dissolvd DMR, Limited - Numeric Violation 0.01 mg/L 0.00 +204% Mar 2021 Resolved
Tetrachloroethylene DMR, Limited - Numeric Violation 0.01 mg/L 0.01 +35% Mar 2021 Resolved
Selenium, potentially dissolvd DMR, Limited - Numeric Violation 0.01 mg/L 0.00 +204% Feb 2021 Resolved
Selenium, potentially dissolvd DMR, Limited - Numeric Violation 0.02 mg/L 0.00 +226% Jan 2021 Resolved
Selenium, potentially dissolvd DMR, Limited - Numeric Violation 0.01 mg/L 0.00 +212% Dec 2020 Resolved
Selenium, potentially dissolvd DMR, Limited - Numeric Violation 0.01 mg/L 0.00 +197% Nov 2020 Resolved
Selenium, potentially dissolvd DMR, Limited - Numeric Violation 0.01 mg/L 0.00 +204% Sep 2020 Resolved
Arsenic, total recoverable DMR, Limited - Numeric Violation 0.01 mg/L 0.00 +67% Sep 2020 Resolved
Arsenic, total recoverable DMR, Limited - Numeric Violation 0.01 mg/L 0.00 +67% Aug 2020 Resolved